Fire risk assessment is not optional. It is a legal duty placed on every person who has control of non-domestic premises across all four nations of the United Kingdom. For holiday parks and hospitality premises, the requirements are particularly significant because you are responsible for people who are sleeping in an unfamiliar environment. This guide explains the law, the regional variances, the local council requirements, and the specific challenges that make holiday parks a unique fire safety environment.
Across the entire United Kingdom, fire safety legislation places a mandatory duty on specific individuals to carry out fire risk assessments. These individuals are known by different titles depending on which nation's legislation applies, but the duty itself is universal: if you have control of non-domestic premises, you must assess the risks from fire and take appropriate measures.
The person on whom this duty falls is defined as:
For holiday parks, this will typically be the site owner, the operating company, and/or the park manager. Where multiple parties share control — for example, a management company operating on behalf of a landowner — multiple parties may hold concurrent fire safety duties.
Fire safety legislation is devolved. Each of the four UK nations operates under its own primary legislation and secondary regulations. While the underlying principles are broadly similar — identify hazards, assess risks, implement measures, record findings — the specific legal requirements, terminology, guidance documents, and enforcement structures differ significantly.
| NATION | PRIMARY LEGISLATION | SECONDARY REGULATIONS | DUTY HOLDER TERM | ENFORCING AUTHORITY |
|---|---|---|---|---|
| 🏴 Scotland | Fire (Scotland) Act 2005, Part 3 | Fire Safety (Scotland) Regulations 2006 | Dutyholder | Scottish Fire & Rescue Service (SFRS) |
| 🏴 England | Regulatory Reform (Fire Safety) Order 2005 (as amended) | Fire Safety (England) Regulations 2022; Fire Safety Act 2021; Building Safety Act 2022 (S.156) | Responsible Person | Local Fire & Rescue Authority |
| 🏴 Wales | Regulatory Reform (Fire Safety) Order 2005 (as amended) | Fire Safety Act 2021 (applies to England & Wales); Mobile Homes (Wales) Act 2013 (residential sites) | Responsible Person | Three Welsh Fire & Rescue Services |
| Northern Ireland | Fire and Rescue Services (Northern Ireland) Order 2006 | Fire Safety Regulations (Northern Ireland) 2010 | Appropriate Person | Northern Ireland Fire & Rescue Service (NIFRS) |
Sector-Specific Guidance Documents:
The Grenfell Tower fire of 14 June 2017 fundamentally changed fire safety law in England and Wales. While the legislative response was primarily focused on high-rise residential buildings, several amendments have wider implications for all responsible persons, including holiday park operators.
Fire Safety Act 2021 (England & Wales) — commenced 16 May 2022. Clarified that the Regulatory Reform (Fire Safety) Order 2005 applies to the structure, external walls (including cladding, balconies, and windows), and individual flat entrance doors opening into common parts of multi-occupied residential buildings.
Fire Safety (England) Regulations 2022 — came into force 23 January 2023. Introduced specific new duties for responsible persons of multi-occupied residential buildings, including provision of fire safety instructions to residents, information about fire doors, building plans to fire services, and regular checks on firefighting equipment.
Building Safety Act 2022, Section 156 — came into force 1 October 2023. Made critical amendments to the Fire Safety Order affecting all regulated premises:
Impact on Scotland: Scotland's legislation already required recording of significant findings where 5+ employees are employed or the premises are subject to licensing or registration. The Scottish Government has not replicated the universal recording requirement introduced in England, but given that most holiday parks fall within the licensing/registration categories, the practical difference for the holiday park sector is minimal.
Impact on Northern Ireland: Northern Ireland's legislation mirrors the Scottish approach. The Fire and Rescue Services (NI) Order 2006 requires recording in similar circumstances. Post-Grenfell amendments have not been applied to the NI framework at the same pace as England.
While the core duty — assess fire risks, implement measures, keep records — is consistent across the UK, the detail varies in ways that matter operationally. The following highlights the key differences that holiday park operators must understand.
Beyond the fire safety legislation itself, holiday parks must hold a caravan site licence issued by their local authority under the Caravan Sites and Control of Development Act 1960. This licence typically includes conditions relating to fire safety, and these conditions can vary between councils.
What Varies Between Councils:
Scotland-Specific: The Civic Government (Scotland) Act 1982 (Licensing of Short-term Lets) Order 2022 introduced mandatory licensing for short-term lets from 1 October 2022. Individual letting units on holiday parks that are marketed as self-catering accommodation may fall within the scope of this licensing regime. The STL licence application requires confirmation that a fire risk assessment is in place.
Wales-Specific: The Development of Tourism and Regulation of Visitor Accommodation (Wales) Bill will introduce a new licensing framework from 2026/27. This will require providers of self-contained visitor accommodation to hold a licence and demonstrate compliance with "fitness for visitor accommodation" standards, including fire risk assessment, gas/electrical safety certificates, carbon monoxide alarms, and public liability insurance.
Holiday parks present a unique fire safety environment that differs significantly from hotels, offices, or other non-domestic premises. The Scottish Government's Annex 3 and the English Model Standards provide specific guidance, but the following factors make holiday parks a distinct fire risk assessment challenge:
Guests are sleeping in an unfamiliar environment. They do not know the layout, the escape routes, or the fire safety systems. They may have consumed alcohol. They may be unfamiliar with LPG appliances. Children and elderly visitors may be present. The Scottish guidance explicitly identifies "short-term occupiers of premises where there is no day-to-day management control or supervision" as a specific risk category.
Fire can spread rapidly between caravans and lodges. Minimum separation of 6m between units (5m for aluminium-clad units with fire-resistant properties). Porches may protrude 1m into the gap. Awnings must maintain 3m clearance to adjacent units. Eaves and bay windows may reduce the gap to a minimum of 5.25m between extremities. One car maximum between adjoining units. No combustible storage beneath or between units.
No unit or site building should be more than 30m from a fire point. Fire points must be weatherproofed, easily accessible, and conspicuously marked "FIRE POINT". Where water supply permits (sufficient pressure for a 5-6m jet at 30 litres/min), standpipes with 30m hose reels must be provided. Where water supply is insufficient, alternative provision of 2x 9-litre water extinguishers or 500-litre water tanks is required. Each fire point must have a manual alarm device.
Many holiday units rely on LPG for heating and cooking. Storage and use must comply with LPGA codes of practice. Exposed gas cylinders must not be within the separation boundary of an adjoining unit. Metered supplies from common storage tanks have additional requirements. The interaction of LPG with the fire triangle (ignition source + fuel + oxygen) creates a heightened risk profile unique to holiday park environments.
Grass and vegetation must be cut at frequent intervals to prevent fire spread. Open fires should be prohibited or strictly controlled. BBQ facilities should be restricted to purpose-designed areas, remote from units. Waste storage must use purpose-designed containers with regular removal. The space beneath caravans must be kept clear of combustible materials.
Emergency vehicles must be able to reach within 50m (Scotland) or 90m (England Model Standards 2008) of any unit. Site roads must be adequate for fire appliance access. Road widths, turning circles, and height clearances must accommodate emergency vehicles. Gateways must be a minimum of 3.1m wide with 3.7m height clearance.
Individual letting units require appropriate automatic fire detection. For smaller self-catering units, a Grade F1 system (long-life sealed battery) under BS 5839 Part 6 may be suitable. Larger premises or those with higher risk profiles may require BS 5839 Part 1 Category L2 systems. Sounders must achieve 75 dB(A) at the bed-head to rouse sleeping occupants. Site-wide alarm arrangements may be needed for larger parks.
Fire action notices must be displayed in every letting unit and at key locations across the site. Notices must indicate: evacuation procedure, alarm location, fire assembly point, and emergency contact numbers. Site plans showing fire points, assembly points, and emergency routes should be prominently displayed. Guests should receive fire safety information at check-in — verbally, in writing, or via a welcome pack.
The Scottish Government's guidance and the Home Office guides both follow a structured five-step approach to fire risk assessment. While the language and chapter structure varies between nations, the core methodology is consistent:
The SafeFRA.PRO+ module structures the assessment form around these steps, expanded into 12 detailed sections that align with the Scottish Government's chapter structure while maintaining compatibility with the Home Office approach used in England, Wales, and Northern Ireland.
Recording:
Review Frequency: No fixed statutory interval is prescribed in any UK nation. However, the consensus across all guidance documents is that FRAs should be reviewed:
Competence of Assessors: Both the Scottish Government and SFRS recommend using assessors who are third-party certificated by a UKAS-accredited certification body or registered with a Professional Registration Scheme. In England, the BAFE SP205 scheme provides a recognised standard. There is no statutory requirement to use a registered assessor — dutyholders may assess their own premises if competent to do so — but the use of unqualified assessors has been identified as a significant concern across the sector.
The consequences of failing to comply with fire safety legislation are severe and have been strengthened significantly in recent years.
| OFFENCE | SCOTLAND | ENGLAND & WALES | NORTHERN IRELAND |
|---|---|---|---|
| Failure to carry out FRA | Fine and/or imprisonment | Unlimited fine and/or up to 2 years imprisonment | Fine and/or imprisonment |
| Failure to comply with enforcement notice | Fine and/or imprisonment up to 2 years | Unlimited fine and/or up to 2 years imprisonment | Fine and/or imprisonment |
| Failure to record FRA findings (where required) | Fine | Unlimited fine (from Oct 2023: applies to ALL premises) | Fine |
| Putting persons at risk of death/serious injury from fire | Unlimited fine and/or imprisonment up to 2 years | Unlimited fine and/or up to 2 years imprisonment | Unlimited fine and/or imprisonment |
| Impersonating an inspector / obstruction | Fine | Unlimited fine (increased from £1,000 in Oct 2023) | Fine |
The legislative landscape described in this document creates a clear picture: fire risk assessment for holiday parks is complex, multi-jurisdictional, and carries serious consequences for non-compliance. It requires not just a one-off form to be completed, but an ongoing, dynamic process of assessment, action, review, and record-keeping across multiple premises and multiple regulatory frameworks.
SafeFRA.PRO+ was built to address these challenges directly: